C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/category/cam-bien/cam-bien-luu-luong/ Cơ Điện Hải Âu - Mua Bán Và Sửa Chữa Thiết B?Điện Dân Dụng & Công Nghiệp Thu, 09 May 2024 02:29:30 +0000 vi hourly 1 //wordpress.org/?v=6.7.2 //issrp.com/wp-content/uploads/2020/04/favicon-100x100.png C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/category/cam-bien/cam-bien-luu-luong/ 32 32 C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fi-1000/ Fri, 25 Mar 2022 08:36:47 +0000 //issrp.com/product/keyence-fi-1000/ COMPLETE PROCESS Display Unit
SKU: FI-1000
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Keyence FI-1000 appeared first on issrp.com.

]]>
Model FI-1000 Display QVGA 2.0 model: color LCD, status indicator light Display update cycle Approx. 10 times/second Network support IO-Link*1 Heat calculation function Unit MJ/h, kW, kBTU/h, GJ/h, MW, MBTU/h*2 Display resolution Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*2 Pulse output increments (MJ) 0.02?99.99*2 Data accumulation Accumulation period Approx. 1 year Data reading USB2.0 Power I/O connector M12 8-pin connector (male) I/O (switchable) Output (Ch1/2/3/4) NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/ch or less, residual voltage 2.5 V or less Analog output (Ch1/2) 4?0 mA/0?0 mA (switchable), load resistance 500 Ω or less External input (Ch2/3) Short circuit current: 1.5 mA or less; input time: 20 ms or more Power supply Power voltage 20?0 VDC, ripple (P-P) 10% included, Class 2/LPS Current consumption 55 mA or less (display unit standalone, excluding load current)*3 Protection circuit Protection against reverse power connection, power supply surges, output short circuits, and output surges Environmental resistance Enclosure rating IP65/IP67 (IEC60529)*4 Ambient temperature ?0°C to +50°C ?°F to +122°F (no freezing) Relative humidity 35?5% RH (no condensation) Vibration resistance 10?00 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions Material Body: PPS / PET / POM; Display window: PAR Weight Approx. 120 g 4.23 oz *1 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*2 Available when the separately sold flow meter FD-R Series and two temperature sensors are connected.*3 455 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (to a maximum of 830 mA or less).*4 When a USB connection is in use, IP65/67 compliance is impaired.

The post Keyence FI-1000 appeared first on issrp.com.

]]>
C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fi-c40f/ Fri, 25 Mar 2022 08:36:16 +0000 //issrp.com/product/keyence-fi-c40f/ Concentration Sensors Pipe type
SKU: FI-C40F
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Keyence FI-C40F appeared first on issrp.com.

]]>
Model FI-C40F Type Pipe type Attachment FI-CF1/3, FI-CF2/4 Detection principle Refractive index (surface light source) Rated concentration range Brix: 0?0% (nD: 1.32500?.41000) Display method Status indicator light Display range Brix: 0?0% Supported fluids Non-corrosive aqueous solutions (such as water-soluble coolants, mold release agents, etc.)*1 Supported fluid temperature 0?0°C 32?58°F (no freezing) Connection diameter FI-CF1: Rc3/4 (20 A); FI-CF3: NPT3/4FI-CF2: Rc1 1/2 (40 A); FI-CF4: NPT1 1/2 Rated pressure range 1.0 MPa or less Pressure resistance 2.0 MPa Display resolution Brix: 0.01/0.1% (default value: 0.1)(nD: 0.00001) Response time 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s Measurement accuracy Brix: ±0.2%*2*3 (nD: ±0.0003) Concentration unit Brix nD*4 Temperature measurement accuracy ±1.0°C 1.8°F*2 Power supply Current consumption 25 mA or less Environmental resistance Enclosure rating IP65/IP67 (IEC60529) Ambient temperature ?0 to +60°C 14 to +140°F (no freezing) Relative humidity 35?5% RH (no condensation) Vibration resistance 10?00 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions Material Liquid end materials Sensor element: sapphireBody: SCS16A; Gasket: FFKM Other materials Body: SUS304; PPS indicator light: PPSU / TPU / PBTCable: PVC Weight Approx. 410 g 14.46 oz *1 Use water as the solvent, and use materials that are soluble in water. If the particles are not water soluble, such as with slurry, the refractive index may not change.*2 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type, condition and temperature of the fluid used by the customer, as well as other factors.*3 This is the value obtained when sucrose solution is used in a constant 20°C 68°F environment, and absolute error and repeatability is taken into account.*4 When using solutions other than sucrose solutions, concentration can be adjusted via span adjustment.

The post Keyence FI-C40F appeared first on issrp.com.

]]>
C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fi-c20d/ Fri, 25 Mar 2022 08:36:11 +0000 //issrp.com/product/keyence-fi-c20d/ Concentration Sensors Probe type
SKU: FI-C20D
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Keyence FI-C20D appeared first on issrp.com.

]]>
Model FI-C20D Type Probe type Attachment ?/td> Detection principle Refractive index (surface light source) Rated concentration range Brix: 0?0% (nD: 1.32500?.37000) Display method Status indicator light Display range Brix: 0?5% Supported fluids Non-corrosive aqueous solutions (such as water-soluble coolants, mold release agents, etc.)*1 Supported fluid temperature 0?0°C 32?58°F (no freezing) Connection diameter ?/td> Rated pressure range Pressure resistance Display resolution Brix: 0.01/0.1% (default value: 0.1)(nD: 0.00001) Response time 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s Measurement accuracy Brix: ±0.2%*2*3 (nD: ±0.0003) Concentration unit Brix nD*4 Temperature measurement accuracy ±1.0°C 1.8°F*2 Power supply Current consumption 25 mA or less Environmental resistance Enclosure rating IP65/IP67 (IEC60529) Ambient temperature ?0 to +60°C 14 to +140°F (no freezing) Relative humidity 35?5% RH (no condensation) Vibration resistance 10?00 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions Material Liquid end materials Sensor element: synthetic quartzBody: aluminum die-cast (nickel chrome plating) / SUS304Pipe: aluminum alloy (anodized); Gasket: FKM Other materials Indicator light: PPSU / TPU / PBTCable: PUR Weight Approx. 480 g 16.93 oz *1 Use water as the solvent, and use materials that are soluble in water. If the particles are not water soluble, such as with slurry, the refractive index may not change.*2 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type, condition and temperature of the fluid used by the customer, as well as other factors.*3 This is the value obtained when sucrose solution is used in a constant 20°C 68°F environment, and absolute error and repeatability is taken into account.*4 When using solutions other than sucrose solutions, concentration can be adjusted via span adjustment.

The post Keyence FI-C20D appeared first on issrp.com.

]]>
C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-h63f/ Fri, 25 Mar 2022 08:36:06 +0000 //issrp.com/product/keyence-fd-h63f/ Flow Sensors Hose model ø48?3
SKU: FD-H63F
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-H63F appeared first on issrp.com.

]]>
Model FD-H63F Type Hose model Supported pipe diameter ø48?3 ø1.89″-2.48″ Supported pipe materials Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1 Supported fluids All fluids (water, oil, chemicals, etc.)*1 Supported fluid temperature 0?00°C 32?12°F (no freezing on pipe surface)*2 Maximum rated flow 500 L/min132.1 gal/min Zero cut flow rate 5.0 L/min1.3 gal/min (variable, initial value) Detection principle Delta TOF Function for automatic correction for speed of sound in liquid ?/td> Display QVGA 2.0 model: color LCD, status indicator light Display update cycle Approx. 10 times/second Display resolution Instantaneous flow 0.01/0.1/1 (L/min) (default value: 1) Integrated flow 0.01/0.1/1 (L) (default value: 1; up to 8 digits) Response time 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s Measurement accuracy ?/td> Repeatability 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4 Hysteresis Variable Flow units L/min m3/h G/min Pulse output increments (L) 0.02?99.99 Pipe temperature measurement accuracy ?/td> Network support IO-Link*5 Heat calculation function Unit MJ/h kW kBTU/h*6 Display resolution Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6 Pulse output increments (MJ) 0.02?99.99*6 Data accumulation Accumulation period Approx. 1 year Data reading USB2.0 Power I/O connector M12 8-pin connector (male) I/O (switchable) Output (Ch1/2/3/4) Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error outputNPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less Analog output (Ch1/2) 4?0 mA/0?0 mA (switchable), load resistance 500 Ω or less External input (Ch2/3) Integrated reset input / flow-rate zero input / zero-point adjustment input / bank inputShort circuit current: 1.5 mA or less; input time: 20 ms or more Power supply Power voltage 20?0 VDC, ripple (P-P) 10% included, Class 2/LPS Current consumption 240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7 Protection circuit Protection against reverse power connection, power supply surges, output short circuits, and output surges Environmental resistance Enclosure rating IP65/67 (IEC 60529)*8 Ambient temperature Sensor head: ?0 to +60°C ? to +140°F (no freezing); Display unit: ?0 to +50°C ? to +122°F (no freezing)*2 Relative humidity 35?5% RH (no condensation) Vibration resistance 10?00 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes Material Display unit Body: PPS/PET/POM; Display window: PAR Sensor head Body: PPS/PET/PAR/SUS304; Cable: PVCSensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7 Weight approx. 1360 g 47.97 oz *1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.*4 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.*5 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*6 Can be used when two temperature sensors (sold separately) are connected.*7 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).*8 When a USB connection is in use, IP65/67 compliance is impaired.

The post Cảm biến lưu lượng Keyence FD-H63F appeared first on issrp.com.

]]>
C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-h47f/ Fri, 25 Mar 2022 08:35:57 +0000 //issrp.com/product/keyence-fd-h47f/ Flow Sensors Hose model ø33?7.9
SKU: FD-H47F
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-H47F appeared first on issrp.com.

]]>
Model FD-H47F Type Hose model Supported pipe diameter ø33?7.9 ø1.299″-1.886″ Supported pipe materials Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1 Supported fluids All fluids (water, oil, chemicals, etc.)*1 Supported fluid temperature 0?00°C 32?12°F (no freezing on pipe surface)*2 Maximum rated flow 300 L/min79.3 gal/min Zero cut flow rate 2.0 L/min0.5 gal/min (variable, initial value) Detection principle Delta TOF Function for automatic correction for speed of sound in liquid ?/td> Display QVGA 2.0 model: color LCD, status indicator light Display update cycle Approx. 10 times/second Display resolution Instantaneous flow 0.01/0.1/1 (L/min) (default value: 1) Integrated flow 0.01/0.1/1 (L) (default value: 1; up to 8 digits) Response time 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s Measurement accuracy ?/td> Repeatability 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4 Hysteresis Variable Flow units L/min m3/h G/min Pulse output increments (L) 0.02?99.99 Pipe temperature measurement accuracy ?/td> Network support IO-Link*5 Heat calculation function Unit MJ/h kW kBTU/h*6 Display resolution Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6 Pulse output increments (MJ) 0.02?99.99*6 Data accumulation Accumulation period Approx. 1 year Data reading USB2.0 Power I/O connector M12 8-pin connector (male) I/O (switchable) Output (Ch1/2/3/4) Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error outputNPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less Analog output (Ch1/2) 4?0 mA/0?0 mA (switchable), load resistance 500 Ω or less External input (Ch2/3) Integrated reset input / flow-rate zero input / zero-point adjustment input / bank inputShort circuit current: 1.5 mA or less; input time: 20 ms or more Power supply Power voltage 20?0 VDC, ripple (P-P) 10% included, Class 2/LPS Current consumption 240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7 Protection circuit Protection against reverse power connection, power supply surges, output short circuits, and output surges Environmental resistance Enclosure rating IP65/67 (IEC 60529)*8 Ambient temperature Sensor head: ?0 to +60°C ? to +140°F (no freezing); Display unit: ?0 to +50°C ? to +122°F (no freezing)*2 Relative humidity 35?5% RH (no condensation) Vibration resistance 10?00 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes Material Display unit Body: PPS/PET/POM; Display window: PAR Sensor head Body: PPS/PET/PAR/SUS304; Cable: PVCSensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7 Weight approx. 1130 g 39.86 oz *1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.*4 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.*5 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*6 Can be used when two temperature sensors (sold separately) are connected.*7 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).*8 When a USB connection is in use, IP65/67 compliance is impaired.

The post Cảm biến lưu lượng Keyence FD-H47F appeared first on issrp.com.

]]>
C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-h32k/ Fri, 25 Mar 2022 08:35:53 +0000 //issrp.com/product/keyence-fd-h32k/ Flow Sensors High-temperature model 25A/32A
SKU: FD-H32K
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-H32K appeared first on issrp.com.

]]>
Model FD-H32K Type High-temperature model Supported pipe diameter 1″ (25A), ø28?7 ø1.10″-1.46″1 1/4″ (32A), ø37?4 ø1.46″-1.73″ Supported pipe materials Metal piping, hard plastic piping*1 Supported fluids All fluids (water, oil, chemicals, etc.)*1 Supported fluid temperature 0?80°C 32?56°F (no freezing on pipe surface)*2*3 Maximum rated flow 1″ (25A) : 200 L/min 52.8 gal/min1 1/4″ (32A) : 300 L/min 79.3 gal/min Zero cut flow rate 1.0 L/min 0.3 gal/min (variable, initial value) Detection principle Delta TOF + Pulse Doppler Function for automatic correction for speed of sound in liquid Yes Display QVGA 2.0 model: color LCD, status indicator light Display update cycle Approx. 10 times/second Display resolution Instantaneous flow 0.01/0.1/1 (L/min) (default value: 1) Integrated flow 0.01/0.1/1 (L) (default value: 1; up to 8 digits) Response time 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s Measurement accuracy Between 10 and 100% of F.S.: ±3.0% of RD*4*5Between 0 and 10% of F.S.: ±0.3% of F.S.*4*5 Repeatability 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*4*6 Hysteresis Variable Flow units L/min m3/h G/min Pulse output increments (L) 0.02?99.99 Pipe temperature measurement accuracy ?/td> Network support IO-Link*7 Heat calculation function Unit MJ/h kW kBTU/h*8 Display resolution Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*8 Pulse output increments (MJ) 0.02?99.99*8 Data accumulation Accumulation period Approx. 1 year Data reading USB2.0 Power I/O connector M12 8-pin connector (male) I/O (switchable) Output (Ch1/2/3/4) Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error outputNPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less Analog output (Ch1/2) 4?0 mA/0?0 mA (switchable), load resistance 500 Ω or less External input (Ch2/3) Integrated reset input / flow-rate zero input / zero-point adjustment input / bank inputShort circuit current: 1.5 mA or less; input time: 20 ms or more Power supply Power voltage 20?0 VDC, ripple (P-P) 10% included, Class 2/LPS Current consumption 240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*9 Protection circuit Protection against reverse power connection, power supply surges, output short circuits, and output surges Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Sensor head: ?0 to +60°C ? to +140°F (no freezing); Display unit: ?0 to +50°C ? to +122°F (no freezing)*2 Relative humidity 35?5% RH (no condensation) Vibration resistance 10?00 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes Material Display unit Body: PPS/PET/POM; Display window: PAR Sensor head Body: PEEK/PPS/PET/PAR/SUS304Sensor element: special rubber; Mounting bracket: SUS304/SUSXM7 Weight approx. 680 g 23.99 oz *1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.*3 When using with fluids at temperatures of 140°C 284°F or greater, equip with the separately sold ultra-high-temperature couplant FD-HK1/HK2/HK3. Furthermore, the display unit must be separated from the sensor based on the de-rating.*4 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.*5 This is the value for when the zero point is adjusted, for a constant 25°C 77°F environment, taking into account the linearity and span error.*6 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.*7 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*8 Can be used when two temperature sensors (sold separately) are connected.*9 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).*10 When a USB connection is in use, IP65/67 compliance is impaired.

The post Cảm biến lưu lượng Keyence FD-H32K appeared first on issrp.com.

]]>
C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-h32f/ Fri, 25 Mar 2022 08:35:50 +0000 //issrp.com/product/keyence-fd-h32f/ Flow Sensors Hose model ø23?2.9
SKU: FD-H32F
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-H32F appeared first on issrp.com.

]]>
Model FD-H32F Type Hose model Supported pipe diameter ø23?2.9 ø0.91″-1.295″ Supported pipe materials Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1 Supported fluids All fluids (water, oil, chemicals, etc.)*1 Supported fluid temperature 0?00°C 32?12°F (no freezing on pipe surface)*2 Maximum rated flow 200 L/min52.8 gal/min Zero cut flow rate 1.0 L/min0.3 gal/min (variable, initial value) Detection principle Delta TOF Function for automatic correction for speed of sound in liquid ?/td> Display QVGA 2.0 model: color LCD, status indicator light Display update cycle Approx. 10 times/second Display resolution Instantaneous flow 0.01/0.1/1 (L/min) (default value: 0.1) Integrated flow 0.01/0.1/1 (L) (default value: 0.1; up to 8 digits) Response time 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s Measurement accuracy ?/td> Repeatability 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4 Hysteresis Variable Flow units L/min m3/h G/min Pulse output increments (L) 0.02?99.99 Pipe temperature measurement accuracy ?/td> Network support IO-Link*5 Heat calculation function Unit MJ/h kW kBTU/h*6 Display resolution Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6 Pulse output increments (MJ) 0.02?99.99*6 Data accumulation Accumulation period Approx. 1 year Data reading USB2.0 Power I/O connector M12 8-pin connector (male) I/O (switchable) Output (Ch1/2/3/4) Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error outputNPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less Analog output (Ch1/2) 4?0 mA/0?0 mA (switchable), load resistance 500 Ω or less External input (Ch2/3) Integrated reset input / flow-rate zero input / zero-point adjustment input / bank inputShort circuit current: 1.5 mA or less; input time: 20 ms or more Power supply Power voltage 20?0 VDC, ripple (P-P) 10% included, Class 2/LPS Current consumption 240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7 Protection circuit Protection against reverse power connection, power supply surges, output short circuits, and output surges Environmental resistance Enclosure rating IP65/67 (IEC 60529)*8 Ambient temperature Sensor head: ?0 to +60°C ? to +140°F (no freezing); Display unit: ?0 to +50°C ? to +122°F (no freezing)*2 Relative humidity 35?5% RH (no condensation) Vibration resistance 10?00 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes Material Display unit Body: PPS/PET/POM; Display window: PAR Sensor head Body: PPS/PET/PAR/SUS304; Cable: PVCSensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7 Weight approx. 880 g 31.04 oz *1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.*4 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.*5 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*6 Can be used when two temperature sensors (sold separately) are connected.*7 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).*8 When a USB connection is in use, IP65/67 compliance is impaired.

The post Cảm biến lưu lượng Keyence FD-H32F appeared first on issrp.com.

]]>
C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-h32/ Fri, 25 Mar 2022 08:35:47 +0000 //issrp.com/product/keyence-fd-h32/ Flow Sensors Standard model 25A/32A
SKU: FD-H32
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-H32 appeared first on issrp.com.

]]>
Model FD-H32 Type Standard model Supported pipe diameter 1″ (25A), ø28?7 ø1.10″-1.46″1 1/4″ (32A), ø37?4 ø1.46″-1.73″ Supported pipe materials Metal piping, hard plastic piping*1 Supported fluids All fluids (water, oil, chemicals, etc.)*1 Supported fluid temperature 0?5°C 32?85°F (no freezing on pipe surface)*2 Maximum rated flow 1″ (25A) : 200 L/min 52.8 gal/min1 1/4″ (32A) : 300 L/min 79.3 gal/min Zero cut flow rate 1.0 L/min 0.3 gal/min (variable, initial value) Detection principle Delta TOF + Pulse Doppler Function for automatic correction for speed of sound in liquid Yes Display QVGA 2.0 model: color LCD, status indicator light Display update cycle Approx. 10 times/second Display resolution Instantaneous flow 0.01/0.1/1 (L/min) (default value: 1) Integrated flow 0.01/0.1/1 (L) (default value: 1; up to 8 digits) Response time 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s Measurement accuracy Between 10 and 100% of F.S.: ±3.0% of RD*3*4Between 0 and 10% of F.S.: ±0.3% of F.S.*3*4 Repeatability 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*5 Hysteresis Variable Flow units L/min m3/h G/min Pulse output increments (L) 0.02?99.99 Pipe temperature measurement accuracy ±2.0°C ±3.5°F (pipe temperature 0?0°C 32?22°F) , ±3.0°C ±5.4°F (pipe temperature 50?5°C 122?85°F) (ambient temperature of 25°C 77°F)*3 Network support IO-Link*6 Heat calculation function Unit MJ/h kW kBTU/h*7 Display resolution Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*7 Pulse output increments (MJ) 0.02?99.99*7 Data accumulation Accumulation period Approx. 1 year Data reading USB2.0 Power I/O connector M12 8-pin connector (male) I/O (switchable) Output (Ch1/2/3/4) Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error outputNPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less Analog output (Ch1/2) 4?0 mA/0?0 mA (switchable), load resistance 500 Ω or less External input (Ch2/3) Integrated reset input / flow-rate zero input / zero-point adjustment input / bank inputShort circuit current: 1.5 mA or less; input time: 20 ms or more Power supply Power voltage 20?0 VDC, ripple (P-P) 10% included, Class 2/LPS Current consumption 240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*8 Protection circuit Protection against reverse power connection, power supply surges, output short circuits, and output surges Environmental resistance Enclosure rating IP65/67 (IEC 60529)*9 Ambient temperature Sensor head: ?0 to +60°C ? to +140°F (no freezing); Display unit: ?0 to +50°C ? to +122°F (no freezing)*2 Relative humidity 35?5% RH (no condensation) Vibration resistance 10?00 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes Material Display unit Body: PPS/PET/POM; Display window: PAR Sensor head Body: PPS/PET/PAR/SUS304Sensor element: special rubber; Mounting bracket: SUS304/SUSXM7 Weight approx. 620 g 21.87 oz *1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.*4 This is the value for when the zero point is adjusted, for a constant 25°C 77°F environment, taking into account the linearity and span error.*5 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.*6 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*7 Can be used when two temperature sensors (sold separately) are connected.*8 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).*9 When a USB connection is in use, IP65/67 compliance is impaired.

The post Cảm biến lưu lượng Keyence FD-H32 appeared first on issrp.com.

]]>
C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-h22f/ Fri, 25 Mar 2022 08:35:42 +0000 //issrp.com/product/keyence-fd-h22f/ Flow Sensors Hose model ø13?2.9
SKU: FD-H22F
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-H22F appeared first on issrp.com.

]]>
Model FD-H22F Type Hose model Supported pipe diameter ø13?2.9 ø0.51″-0.90″ Supported pipe materials Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1 Supported fluids All fluids (water, oil, chemicals, etc.)*1 Supported fluid temperature 0?00°C 32?12°F (no freezing on pipe surface)*2 Maximum rated flow 60 L/min15.9 gal/min Zero cut flow rate 0.5 L/min0.13 gal/min (variable, initial value) Detection principle Delta TOF Function for automatic correction for speed of sound in liquid ?/td> Display QVGA 2.0 model: color LCD, status indicator light Display update cycle Approx. 10 times/second Display resolution Instantaneous flow 0.01/0.1/1 (L/min) (default value: 0.1) Integrated flow 0.01/0.1/1 (L) (default value: 0.1; up to 8 digits) Response time 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s Measurement accuracy ?/td> Repeatability 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4 Hysteresis Variable Flow units L/min m3/h G/min Pulse output increments (L) 0.02?99.99 Pipe temperature measurement accuracy ?/td> Network support IO-Link*5 Heat calculation function Unit MJ/h kW kBTU/h*6 Display resolution Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6 Pulse output increments (MJ) 0.02?99.99*6 Data accumulation Accumulation period Approx. 1 year Data reading USB2.0 Power I/O connector M12 8-pin connector (male) I/O (switchable) Output (Ch1/2/3/4) Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error outputNPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less Analog output (Ch1/2) 4?0 mA/0?0 mA (switchable), load resistance 500 Ω or less External input (Ch2/3) Integrated reset input / flow-rate zero input / zero-point adjustment input / bank inputShort circuit current: 1.5 mA or less; input time: 20 ms or more Power supply Power voltage 20?0 VDC, ripple (P-P) 10% included, Class 2/LPS Current consumption 240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7 Protection circuit Protection against reverse power connection, power supply surges, output short circuits, and output surges Environmental resistance Enclosure rating IP65/67 (IEC 60529)*8 Ambient temperature Sensor head: ?0 to +60°C ? to +140°F (no freezing); Display unit: ?0 to +50°C ? to +122°F (no freezing)*2 Relative humidity 35?5% RH (no condensation) Vibration resistance 10?00 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes Material Display unit Body: PPS/PET/POM; Display window: PAR Sensor head Body: PPS/PET/PAR/SUS304; Cable: PVCSensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7 Weight approx. 770 g 27.16 oz *1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.*4 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.*5 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*6 Can be used when two temperature sensors (sold separately) are connected.*7 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).*8 When a USB connection is in use, IP65/67 compliance is impaired.

The post Cảm biến lưu lượng Keyence FD-H22F appeared first on issrp.com.

]]>
C岷 bi岷縩 l瓢u l瓢峄g Ch铆nh H茫ng, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-h20k/ Fri, 25 Mar 2022 08:35:38 +0000 //issrp.com/product/keyence-fd-h20k/ Flow Sensors High-temperature model 15A/20A
SKU: FD-H20K
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-H20K appeared first on issrp.com.

]]>
Model FD-H20K Type High-temperature model Supported pipe diameter 1/2″ (15A), ø18?3 ø0.71″-0.91″3/4″ (20A), ø23?8 ø0.91″-1.10″ Supported pipe materials Metal piping, hard plastic piping*1 Supported fluids All fluids (water, oil, chemicals, etc.)*1 Supported fluid temperature 0?80°C 32?56°F (no freezing on pipe surface)*2*3 Maximum rated flow 1/2″ (15A) : 60 L/min 15.9 gal/min3/4″ (20A) : 100 L/min 26.4 gal/min Zero cut flow rate 0.5 L/min 0.13 gal/min (variable, initial value) Detection principle Delta TOF + Pulse Doppler Function for automatic correction for speed of sound in liquid Yes Display QVGA 2.0 model: color LCD, status indicator light Display update cycle Approx. 10 times/second Display resolution Instantaneous flow 0.01/0.1/1 (L/min) (default value: 0.1) Integrated flow 0.01/0.1/1 (L) (default value: 0.1; up to 8 digits) Response time 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s Measurement accuracy Between 10 and 100% of F.S.: ±3.0% of RD*4*5Between 0 and 10% of F.S.: ±0.3% of F.S.*4*5 Repeatability 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*4*6 Hysteresis Variable Flow units L/min m3/h G/min Pulse output increments (L) 0.02?99.99 Pipe temperature measurement accuracy ?/td> Network support IO-Link*7 Heat calculation function Unit MJ/h kW kBTU/h*8 Display resolution Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*8 Pulse output increments (MJ) 0.02?99.99*8 Data accumulation Accumulation period Approx. 1 year Data reading USB2.0 Power I/O connector M12 8-pin connector (male) I/O (switchable) Output (Ch1/2/3/4) Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error outputNPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less Analog output (Ch1/2) 4?0 mA/0?0 mA (switchable), load resistance 500 Ω or less External input (Ch2/3) Integrated reset input / flow-rate zero input / zero-point adjustment input / bank inputShort circuit current: 1.5 mA or less; input time: 20 ms or more Power supply Power voltage 20?0 VDC, ripple (P-P) 10% included, Class 2/LPS Current consumption 240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*9 Protection circuit Protection against reverse power connection, power supply surges, output short circuits, and output surges Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Sensor head: ?0 to +60°C ? to +140°F (no freezing); Display unit: ?0 to +50°C ? to +122°F (no freezing)*2 Relative humidity 35?5% RH (no condensation) Vibration resistance 10?00 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes Material Display unit Body: PPS/PET/POM; Display window: PAR Sensor head Body: PEEK/PPS/PET/PAR/SUS304Sensor element: special rubber; Mounting bracket: SUS304/SUSXM7 Weight approx. 540 g 19.05 oz *1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.*3 When using with fluids at temperatures of 140°C 284°F or greater, equip with the separately sold ultra-high-temperature couplant FD-HK1/HK2/HK3. Furthermore, the display unit must be separated from the sensor based on the de-rating.*4 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.*5 This is the value for when the zero point is adjusted, for a constant 25°C 77°F environment, taking into account the linearity and span error.*6 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.*7 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*8 Can be used when two temperature sensors (sold separately) are connected.*9 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).*10 When a USB connection is in use, IP65/67 compliance is impaired.

The post Cảm biến lưu lượng Keyence FD-H20K appeared first on issrp.com.

]]>