Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/series/keyence-fd-g/ Cơ Điện Hải Âu - Mua Bán Và Sửa Chữa Thiết B?Điện Dân Dụng & Công Nghiệp Thu, 09 May 2024 02:25:00 +0000 vi hourly 1 //wordpress.org/?v=6.7.2 //issrp.com/wp-content/uploads/2020/04/favicon-100x100.png Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/series/keyence-fd-g/ 32 32 Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-g80l/ Tue, 11 Jan 2022 08:41:17 +0000 //issrp.com/product/keyence-fd-g80l/ Clamp-On Gas Flow Meter DN 65A/80A
SKU: FD-G80L
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-G80L appeared first on issrp.com.

]]>
Model FD-G80L Pipe size DN (Diameter Nominal) 65 A, 80 A NPS (Nominal Pipe Size) 2 1/2″, 3″ Outer diameter of pipe ø72 to 78 mm 2.83″ to 3.07″, ø86 to 92 mm 3.39″ to 3.62″ Pipe thickness 2.0 to 4.0 mm 0.08″ to 0.16″ Supported pipe materials Iron, steel, stainless steel Supported fluids Air, Nitrogen, other gases*1 Fluid temperature 0 to 60ºC 32 to 140 °F Recommended pressure 0.4 MPa or greater (58 PSI or greater) Rated velocity of flow range Up to 15 m/s Actual flow rate range (typical) m3/h Pipe size 65 A: 200.0Pipe size 80 A: 280.0 L/min Pipe size 65 A: 3300Pipe size 80 A: 4600 CFM Pipe size 65 A: 120.00Pipe size 80 A: 160.00 Standard flow rate range (typical) [CFM] 20°C 68°F 60 psi 0.41 MPa Pipe size 65 A: 568.43Pipe size 80 A: 757.91 20°C 68°F 80 psi 0.55 MPa Pipe size 65 A: 720.64Pipe size 80 A: 960.85 20°C 68°F 100 psi 0.69 MPa Pipe size 65 A: 872.84Pipe size 80 A: 1163.79 20°C 68°F 120 psi 0.83 MPa Pipe size 65 A: 1025.05Pipe size 80 A: 1366.73 Display QVGA 2.2″ LCD color monitor Display update cycle Approx. 3 Hz Display resolution Instantaneous flow rate 0.1 m3/h, 1 L/min, 0.01 CFM Consumption/leakage amount 0.01 m3, 1 L, 1 CF Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) Measurement accuracy Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5 Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5 Zero point error ±0.15% of F.S.*2*6 Static leakage repeatability ±1.0% of RD*4*7 Hysteresis Variable Flow units CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min I/O wiring connection port M12 4-pin connector (male) Detection mode (switchable) ch.1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 ch.2 Instantaneous flow mode/area mode/pulse (? mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 Standard I/O (switchable) Control output (ch.1/ch.2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less Analog output (ch.2) 4 to 20 mA/0 to 20 mA, load resistance: 500 ?or less External input (ch.2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100?or less Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) Communication interface USB USB 2.0 Ethernet Standard IEEE 802.3u (100BASE-TX) Transmission rate 100 Mbps Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable Connector M12 connector (female, D-code) Network function Modbus TCP, EtherNet/IPTM, IO-Link*9 Recording capacity Consumption amount/ leakage amount Approx. 5 years Events 100 Power supply Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2 Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Detection head: ?0 to +60°C 14 to 140°F (no freezing), display unit: ?0 to +55°C 14 to 131°F (no freezing) Relative humidity 5 to 85%RH (no condensation) Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes Shock resistance 100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis Material Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating Detection head Body: PPS/SUS304, rear surface: rubber Mounting/damping bracket SUS304 Weight Approx. 3.6 kg *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.*5 The linearity error characteristic due to the pipe is not included in this value.*6 It is possible to reduce zero point errors by performing an origin adjustment.*7 This is the value within the range where measurement accuracy is guaranteed.*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.?ch.1: Pulse(+) mode?ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*10 The IP65/67 enclosure rating is lost when a USB connection is established.

The post Cảm biến lưu lượng Keyence FD-G80L appeared first on issrp.com.

]]>
Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-g80/ Tue, 11 Jan 2022 08:41:11 +0000 //issrp.com/product/keyence-fd-g80/ Clamp-On Gas Flow Meter DN 65A/80A
SKU: FD-G80
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-G80 appeared first on issrp.com.

]]>
Model FD-G80 Pipe size DN (Diameter Nominal) 65 A, 80 A NPS (Nominal Pipe Size) 2 1/2″, 3″ Outer diameter of pipe ø72 to 78 mm 2.83″ to 3.07″, ø86 to 92 mm 3.39″ to 3.62″ Pipe thickness 2.9 to 6.3 mm 0.114″ to 0.25″ Supported pipe materials Iron, steel, stainless steel Supported fluids Air, Nitrogen, other gases*1 Fluid temperature 0 to 60ºC 32 to 140 °F Recommended pressure 0.4 MPa or greater (58 PSI or greater) Rated velocity of flow range Up to 15 m/s Actual flow rate range (typical) m3/h Pipe size 65 A: 200.0Pipe size 80 A: 280.0 L/min Pipe size 65 A: 3300Pipe size 80 A: 4600 CFM Pipe size 65 A: 120.00Pipe size 80 A: 160.00 Standard flow rate range (typical) [CFM] 20°C 68°F 60 psi 0.41 MPa Pipe size 65 A: 568.43Pipe size 80 A: 757.91 20°C 68°F 80 psi 0.55 MPa Pipe size 65 A: 720.64Pipe size 80 A: 960.85 20°C 68°F 100 psi 0.69 MPa Pipe size 65 A: 872.84Pipe size 80 A: 1163.79 20°C 68°F 120 psi 0.83 MPa Pipe size 65 A: 1025.05Pipe size 80 A: 1366.73 Display QVGA 2.2″ LCD color monitor Display update cycle Approx. 3 Hz Display resolution Instantaneous flow rate 0.1 m3/h, 1 L/min, 0.01 CFM Consumption/leakage amount 0.01 m3, 1 L, 1 CF Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) Measurement accuracy Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5 Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5 Zero point error ±0.15% of F.S.*2*6 Static leakage repeatability ±1.0% of RD*4*7 Hysteresis Variable Flow units CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min I/O wiring connection port M12 4-pin connector (male) Detection mode (switchable) ch.1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 ch.2 Instantaneous flow mode/area mode/pulse (? mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 Standard I/O (switchable) Control output (ch.1/ch.2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less Analog output (ch.2) 4 to 20 mA/0 to 20 mA, load resistance: 500 ?or less External input (ch.2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100?or less Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) Communication interface USB USB 2.0 Ethernet Standard IEEE 802.3u (100BASE-TX) Transmission rate 100 Mbps Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable Connector M12 connector (female, D-code) Network function Modbus TCP, EtherNet/IPTM, IO-Link*9 Recording capacity Consumption amount/ leakage amount Approx. 5 years Events 100 Power supply Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2 Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Detection head: ?0 to +60°C 14 to 140°F (no freezing), display unit: ?0 to +55°C 14 to 131°F (no freezing) Relative humidity 5 to 85%RH (no condensation) Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes Shock resistance 100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis Material Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating Detection head Body: PPS/SUS304, rear surface: rubber Mounting/damping bracket SUS304 Weight Approx. 3.6 kg *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.*5 The linearity error characteristic due to the pipe is not included in this value.*6 It is possible to reduce zero point errors by performing an origin adjustment.*7 This is the value within the range where measurement accuracy is guaranteed.*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.?ch.1: Pulse(+) mode?ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*10 The IP65/67 enclosure rating is lost when a USB connection is established.

The post Cảm biến lưu lượng Keyence FD-G80 appeared first on issrp.com.

]]>
Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-g50l/ Tue, 11 Jan 2022 08:41:08 +0000 //issrp.com/product/keyence-fd-g50l/ Clamp-On Gas Flow Meter DN 32A/40A/50A
SKU: FD-G50L
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-G50L appeared first on issrp.com.

]]>
Model FD-G50L Pipe size DN (Diameter Nominal) 32 A, 40 A, 50 A NPS (Nominal Pipe Size) 1 1/4″, 1 1/2″, 2″ Outer diameter of pipe ø41 to 45 mm 1.61″ to 1.77″, ø47 to 51 mm 1.85″ to 2.01″, ø58 to 62 mm 2.28″ to 2.44″ Pipe thickness 1.65 to 3.5 mm 0.06″ to 0.138″ Supported pipe materials Iron, steel, stainless steel Supported fluids Air, Nitrogen, other gases*1 Fluid temperature 0 to 60ºC 32 to 140 °F Recommended pressure 0.4 MPa or greater (58 PSI or greater) Rated velocity of flow range Up to 15 m/s Actual flow rate range (typical) m3/h Pipe size 32 A: 54.00Pipe size 40 A: 72.00Pipe size 50 A: 120.00 L/min Pipe size 32 A: 900.0Pipe size 40 A: 1200.0Pipe size 50 A: 2000.0 CFM Pipe size 32 A: 32.00Pipe size 40 A: 42.00Pipe size 50 A: 70.00 Standard flow rate range (typical) [CFM] 20°C 68°F 60 psi 0.41 MPa Pipe size 32 A: 151.58Pipe size 40 A: 198.95Pipe size 50 A: 331.58 20°C 68°F 80 psi 0.55 MPa Pipe size 32 A: 192.17Pipe size 40 A: 252.22Pipe size 50 A: 420.37 20°C 68°F 100 psi 0.69 MPa Pipe size 32 A: 232.76Pipe size 40 A: 305.49Pipe size 50 A: 509.16 20°C 68°F 120 psi 0.83 MPa Pipe size 32 A: 273.35Pipe size 40 A: 358.77Pipe size 50 A: 597.95 Display QVGA 2.2″ LCD color monitor Display update cycle Approx. 3 Hz Display resolution Instantaneous flow rate 0.01 m3/h, 0.1 L/min, 0.01 CFM Consumption/leakage amount 0.01 m3, 1 L, 0.1 CF Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) Measurement accuracy Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5 Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5 Zero point error ±0.15% of F.S.*2*6 Static leakage repeatability ±1.0% of RD*4*7 Hysteresis Variable Flow units CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min I/O wiring connection port M12 4-pin connector (male) Detection mode (switchable) ch.1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 ch.2 Instantaneous flow mode/area mode/pulse (? mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 Standard I/O (switchable) Control output (ch.1/ch.2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less Analog output (ch.2) 4 to 20 mA/0 to 20 mA, load resistance: 500 ?or less External input (ch.2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100?or less Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) Communication interface USB USB 2.0 Ethernet Standard IEEE 802.3u (100BASE-TX) Transmission rate 100 Mbps Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable Connector M12 connector (female, D-code) Network function Modbus TCP, EtherNet/IPTM, IO-Link*9 Recording capacity Consumption amount/ leakage amount Approx. 5 years Events 100 Power supply Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2 Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Detection head: ?0 to +60°C 14 to 140°F (no freezing), display unit: ?0 to +55°C 14 to 131°F (no freezing) Relative humidity 5 to 85%RH (no condensation) Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes Shock resistance 100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis Material Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating Detection head Body: PPS/SUS304, rear surface: rubber Mounting/damping bracket SUS304 Weight Approx. 2.7 kg *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.*5 The linearity error characteristic due to the pipe is not included in this value.*6 It is possible to reduce zero point errors by performing an origin adjustment.*7 This is the value within the range where measurement accuracy is guaranteed.*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.?ch.1: Pulse(+) mode?ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*10 The IP65/67 enclosure rating is lost when a USB connection is established.

The post Cảm biến lưu lượng Keyence FD-G50L appeared first on issrp.com.

]]>
Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-g50/ Tue, 11 Jan 2022 08:41:01 +0000 //issrp.com/product/keyence-fd-g50/ Clamp-On Gas Flow Meter DN 32A/40A/50A
SKU: FD-G50
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-G50 appeared first on issrp.com.

]]>
Model FD-G50 Pipe size DN (Diameter Nominal) 32 A, 40 A, 50 A NPS (Nominal Pipe Size) 1 1/4″, 1 1/2″, 2″ Outer diameter of pipe ø41 to 45 mm 1.61″ to 1.77″, ø47 to 51 mm 1.85″ to 2.01″, ø58 to 62 mm 2.28″ to 2.44″ Pipe thickness 2.4 to 5.7 mm 0.09″ to 0.22″ Supported pipe materials Iron, steel, stainless steel Supported fluids Air, Nitrogen, other gases*1 Fluid temperature 0 to 60ºC 32 to 140 °F Recommended pressure 0.4 MPa or greater (58 PSI or greater) Rated velocity of flow range Up to 15 m/s Actual flow rate range (typical) m3/h Pipe size 32 A: 54.00Pipe size 40 A: 72.00Pipe size 50 A: 120.00 L/min Pipe size 32 A: 900.0Pipe size 40 A: 1200.0Pipe size 50 A: 2000.0 CFM Pipe size 32 A: 32.00Pipe size 40 A: 42.00Pipe size 50 A: 70.00 Standard flow rate range (typical) [CFM] 20°C 68°F 60 psi 0.41 MPa Pipe size 32 A: 151.58Pipe size 40 A: 198.95Pipe size 50 A: 331.58 20°C 68°F 80 psi 0.55 MPa Pipe size 32 A: 192.17Pipe size 40 A: 252.22Pipe size 50 A: 420.37 20°C 68°F 100 psi 0.69 MPa Pipe size 32 A: 232.76Pipe size 40 A: 305.49Pipe size 50 A: 509.16 20°C 68°F 120 psi 0.83 MPa Pipe size 32 A: 273.35Pipe size 40 A: 358.77Pipe size 50 A: 597.95 Display QVGA 2.2″ LCD color monitor Display update cycle Approx. 3 Hz Display resolution Instantaneous flow rate 0.01 m3/h, 0.1 L/min, 0.01 CFM Consumption/leakage amount 0.01 m3, 1 L, 0.1 CF Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) Measurement accuracy Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5 Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5 Zero point error ±0.15% of F.S.*2*6 Static leakage repeatability ±1.0% of RD*4*7 Hysteresis Variable Flow units CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min I/O wiring connection port M12 4-pin connector (male) Detection mode (switchable) ch.1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 ch.2 Instantaneous flow mode/area mode/pulse (? mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 Standard I/O (switchable) Control output (ch.1/ch.2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less Analog output (ch.2) 4 to 20 mA/0 to 20 mA, load resistance: 500 ?or less External input (ch.2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100?or less Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) Communication interface USB USB 2.0 Ethernet Standard IEEE 802.3u (100BASE-TX) Transmission rate 100 Mbps Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable Connector M12 connector (female, D-code) Network function Modbus TCP, EtherNet/IPTM, IO-Link*9 Recording capacity Consumption amount/ leakage amount Approx. 5 years Events 100 Power supply Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2 Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Detection head: ?0 to +60°C 14 to 140°F (no freezing), display unit: ?0 to +55°C 14 to 131°F (no freezing) Relative humidity 5 to 85%RH (no condensation) Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes Shock resistance 100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis Material Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating Detection head Body: PPS/SUS304, rear surface: rubber Mounting/damping bracket SUS304 Weight Approx. 2.7 kg *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.*5 The linearity error characteristic due to the pipe is not included in this value.*6 It is possible to reduce zero point errors by performing an origin adjustment.*7 This is the value within the range where measurement accuracy is guaranteed.*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.?ch.1: Pulse(+) mode?ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*10 The IP65/67 enclosure rating is lost when a USB connection is established.

The post Cảm biến lưu lượng Keyence FD-G50 appeared first on issrp.com.

]]>
Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-g25l/ Tue, 11 Jan 2022 08:40:58 +0000 //issrp.com/product/keyence-fd-g25l/ Clamp-On Gas Flow Meter DN 20A/25A
SKU: FD-G25L
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-G25L appeared first on issrp.com.

]]>
Model FD-G25L Pipe size DN (Diameter Nominal) 20 A, 25 A NPS (Nominal Pipe Size) 3/4″, 1″ Outer diameter of pipe ø25 to 29 mm 0.98″ to 1.14″, ø32 to 36 mm 1.26″ to 1.42″ Pipe thickness 1.5 to 3.0 mm 0.06″ to 0.118″ Supported pipe materials Iron, steel, stainless steel Supported fluids Air, Nitrogen, other gases*1 Fluid temperature 0 to 60ºC 32 to 140 °F Recommended pressure 0.4 MPa or greater (58 PSI or greater) Rated velocity of flow range Up to 15 m/s Actual flow rate range (typical) m3/h Pipe size 20 A: 20.00Pipe size 25 A: 32.00 L/min Pipe size 20 A: 330.0Pipe size 25 A: 540.0 CFM Pipe size 20 A: 12.00Pipe size 25 A: 19.00 Standard flow rate range (typical) [CFM] 20°C 68°F 60 psi 0.41 MPa Pipe size 20 A: 56.84Pipe size 25 A: 90.00 20°C 68°F 80 psi 0.55 MPa Pipe size 20 A: 72.06Pipe size 25 A: 114.10 20°C 68°F 100 psi 0.69 MPa Pipe size 20 A: 87.28Pipe size 25 A: 138.20 20°C 68°F 120 psi 0.83 MPa Pipe size 20 A: 102.50Pipe size 25 A: 162.30 Display QVGA 2.2″ LCD color monitor Display update cycle Approx. 3 Hz Display resolution Instantaneous flow rate 0.01 m3/h, 0.1 L/min, 0.001 CFM Consumption/leakage amount 0.001 m3, 1 L, 0.1 CF Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) Measurement accuracy Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5 Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5 Zero point error ±0.15% of F.S.*2*6 Static leakage repeatability ±1.0% of RD*4*7 Hysteresis Variable Flow units CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min I/O wiring connection port M12 4-pin connector (male) Detection mode (switchable) ch.1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 ch.2 Instantaneous flow mode/area mode/pulse (? mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 Standard I/O (switchable) Control output (ch.1/ch.2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less Analog output (ch.2) 4 to 20 mA/0 to 20 mA, load resistance: 500 ?or less External input (ch.2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100?or less Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) Communication interface USB USB 2.0 Ethernet Standard IEEE 802.3u (100BASE-TX) Transmission rate 100 Mbps Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable Connector M12 connector (female, D-code) Network function Modbus TCP, EtherNet/IPTM, IO-Link*9 Recording capacity Consumption amount/ leakage amount Approx. 5 years Events 100 Power supply Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2 Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Detection head: ?0 to +60°C 14 to 140°F (no freezing), display unit: ?0 to +55°C 14 to 131°F (no freezing) Relative humidity 5 to 85%RH (no condensation) Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes Shock resistance 100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis Material Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating Detection head Body: PPS/SUS304, rear surface: rubber Mounting/damping bracket SUS304 Weight Approx. 2.2 kg *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.*5 The linearity error characteristic due to the pipe is not included in this value.*6 It is possible to reduce zero point errors by performing an origin adjustment.*7 This is the value within the range where measurement accuracy is guaranteed.*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.?ch.1: Pulse(+) mode?ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*10 The IP65/67 enclosure rating is lost when a USB connection is established.

The post Cảm biến lưu lượng Keyence FD-G25L appeared first on issrp.com.

]]>
Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-g25/ Tue, 11 Jan 2022 08:40:51 +0000 //issrp.com/product/keyence-fd-g25/ Clamp-On Gas Flow Meter DN 20A/25A
SKU: FD-G25
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-G25 appeared first on issrp.com.

]]>
Model FD-G25 Pipe size DN (Diameter Nominal) 20 A, 25 A NPS (Nominal Pipe Size) 3/4″, 1″ Outer diameter of pipe ø25 to 29 mm 0.98″ to 1.14″, ø32 to 36 mm 1.26″ to 1.42″ Pipe thickness 2.0 to 4.5 mm 0.08″ to 0.18″ Supported pipe materials Iron, steel, stainless steel Supported fluids Air, Nitrogen, other gases*1 Fluid temperature 0 to 60ºC 32 to 140 °F Recommended pressure 0.4 MPa or greater (58 PSI or greater) Rated velocity of flow range Up to 15 m/s Actual flow rate range (typical) m3/h Pipe size 20 A: 20.00Pipe size 25 A: 32.00 L/min Pipe size 20 A: 330.0Pipe size 25 A: 540.0 CFM Pipe size 20 A: 12.00Pipe size 25 A: 19.00 Standard flow rate range (typical) [CFM] 20°C 68°F 60 psi 0.41 MPa Pipe size 20 A: 56.84Pipe size 25 A: 90.00 20°C 68°F 80 psi 0.55 MPa Pipe size 20 A: 72.06Pipe size 25 A: 114.10 20°C 68°F 100 psi 0.69 MPa Pipe size 20 A: 87.28Pipe size 25 A: 138.20 20°C 68°F 120 psi 0.83 MPa Pipe size 20 A: 102.50Pipe size 25 A: 162.30 Display QVGA 2.2″ LCD color monitor Display update cycle Approx. 3 Hz Display resolution Instantaneous flow rate 0.01 m3/h, 0.1 L/min, 0.001 CFM Consumption/leakage amount 0.001 m3, 1 L, 0.1 CF Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) Measurement accuracy Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5 Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5 Zero point error ±0.15% of F.S.*2*6 Static leakage repeatability ±1.0% of RD*4*7 Hysteresis Variable Flow units CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min I/O wiring connection port M12 4-pin connector (male) Detection mode (switchable) ch.1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 ch.2 Instantaneous flow mode/area mode/pulse (? mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 Standard I/O (switchable) Control output (ch.1/ch.2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less Analog output (ch.2) 4 to 20 mA/0 to 20 mA, load resistance: 500 ?or less External input (ch.2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100?or less Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) Communication interface USB USB 2.0 Ethernet Standard IEEE 802.3u (100BASE-TX) Transmission rate 100 Mbps Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable Connector M12 connector (female, D-code) Network function Modbus TCP, EtherNet/IPTM, IO-Link*9 Recording capacity Consumption amount/ leakage amount Approx. 5 years Events 100 Power supply Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2 Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Detection head: ?0 to +60°C 14 to 140°F (no freezing), display unit: ?0 to +55°C 14 to 131°F (no freezing) Relative humidity 5 to 85%RH (no condensation) Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes Shock resistance 100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis Material Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating Detection head Body: PPS/SUS304, rear surface: rubber Mounting/damping bracket SUS304 Weight Approx. 2.2 kg *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.*5 The linearity error characteristic due to the pipe is not included in this value.*6 It is possible to reduce zero point errors by performing an origin adjustment.*7 This is the value within the range where measurement accuracy is guaranteed.*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.?ch.1: Pulse(+) mode?ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*10 The IP65/67 enclosure rating is lost when a USB connection is established.

The post Cảm biến lưu lượng Keyence FD-G25 appeared first on issrp.com.

]]>
Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-g200l/ Tue, 11 Jan 2022 08:40:40 +0000 //issrp.com/product/keyence-fd-g200l/ Clamp-On Gas Flow Meter DN 150A/200A
SKU: FD-G200L
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-G200L appeared first on issrp.com.

]]>
Model FD-G200L Pipe size DN (Diameter Nominal) 150 A, 200 A NPS (Nominal Pipe Size) 6″, 8″ Outer diameter of pipe ø163 to 171 mm 6.42″ to 6.73″, ø214 to 222 mm 8.43″ to 8.74″ Pipe thickness 2.8 to 5.0 mm 0.11″ to 0.2″ Supported pipe materials Iron, steel, stainless steel Supported fluids Air, Nitrogen, other gases*1 Fluid temperature 0 to 60ºC 32 to 140 °F Recommended pressure 0.4 MPa or greater (58 PSI or greater) Rated velocity of flow range Up to 15 m/s Actual flow rate range (typical) m3/h Pipe size 150 A: 1000.0Pipe size 200 A: 1800.0 L/min Pipe size 150 A: 17000Pipe size 200 A: 30000 CFM Pipe size 150 A: 600.00Pipe size 200 A: 1100.00 Standard flow rate range (typical) [CFM] 20°C 68°F 60 psi 0.41 MPa Pipe size 150 A: 2842.15Pipe size 200 A: 5210.62 20°C 68°F 80 psi 0.55 MPa Pipe size 150 A: 3603.18Pipe size 200 A: 6605.84 20°C 68°F 100 psi 0.69 MPa Pipe size 150 A: 4364.21Pipe size 200 A: 8001.06 20°C 68°F 120 psi 0.83 MPa Pipe size 150 A: 5125.24Pipe size 200 A: 9396.28 Display QVGA 2.2″ LCD color monitor Display update cycle Approx. 3 Hz Display resolution Instantaneous flow rate 0.1 m3/h, 1 L/min, 0.1 CFM Consumption/leakage amount 0.1 m3, 1 L, 1 CF Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) Measurement accuracy Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5 Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5 Zero point error ±0.15% of F.S.*2*6 Static leakage repeatability ±1.0% of RD*4*7 Hysteresis Variable Flow units CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min I/O wiring connection port M12 4-pin connector (male) Detection mode (switchable) ch.1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 ch.2 Instantaneous flow mode/area mode/pulse (? mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 Standard I/O (switchable) Control output (ch.1/ch.2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less Analog output (ch.2) 4 to 20 mA/0 to 20 mA, load resistance: 500 ?or less External input (ch.2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100?or less Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) Communication interface USB USB 2.0 Ethernet Standard IEEE 802.3u (100BASE-TX) Transmission rate 100 Mbps Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable Connector M12 connector (female, D-code) Network function Modbus TCP, EtherNet/IPTM, IO-Link*9 Recording capacity Consumption amount/ leakage amount Approx. 5 years Events 100 Power supply Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2 Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Detection head: ?0 to +60°C 14 to 140°F (no freezing), display unit: ?0 to +55°C 14 to 131°F (no freezing) Relative humidity 5 to 85%RH (no condensation) Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes Shock resistance 100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis Material Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating Detection head Body: PPS/SUS304, rear surface: rubber Mounting/damping bracket SUS304 Weight Approx. 2.8 kg *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.*5 The linearity error characteristic due to the pipe is not included in this value.*6 It is possible to reduce zero point errors by performing an origin adjustment.*7 This is the value within the range where measurement accuracy is guaranteed.*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.?ch.1: Pulse(+) mode?ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*10 The IP65/67 enclosure rating is lost when a USB connection is established.

The post Cảm biến lưu lượng Keyence FD-G200L appeared first on issrp.com.

]]>
Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-g200/ Tue, 11 Jan 2022 08:40:37 +0000 //issrp.com/product/keyence-fd-g200/ Clamp-On Gas Flow Meter DN 150A/200A
SKU: FD-G200
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-G200 appeared first on issrp.com.

]]>
Model FD-G200 Pipe size DN (Diameter Nominal) 150 A, 200 A NPS (Nominal Pipe Size) 6″, 8″ Outer diameter of pipe ø163 to 171 mm 6.42″ to 6.73″, ø214 to 222 mm 8.43″ to 8.74″ Pipe thickness 3.5 to 8.7 mm 0.14″ to 0.34″ Supported pipe materials Iron, steel, stainless steel Supported fluids Air, Nitrogen, other gases*1 Fluid temperature 0 to 60ºC 32 to 140 °F Recommended pressure 0.4 MPa or greater (58 PSI or greater) Rated velocity of flow range Up to 15 m/s Actual flow rate range (typical) m3/h Pipe size 150 A: 1000.0Pipe size 200 A: 1800.0 L/min Pipe size 150 A: 17000Pipe size 200 A: 30000 CFM Pipe size 150 A: 600.00Pipe size 200 A: 1100.00 Standard flow rate range (typical) [CFM] 20°C 68°F 60 psi 0.41 MPa Pipe size 150 A: 2842.15Pipe size 200 A: 5210.62 20°C 68°F 80 psi 0.55 MPa Pipe size 150 A: 3603.18Pipe size 200 A: 6605.84 20°C 68°F 100 psi 0.69 MPa Pipe size 150 A: 4364.21Pipe size 200 A: 8001.06 20°C 68°F 120 psi 0.83 MPa Pipe size 150 A: 5125.24Pipe size 200 A: 9396.28 Display QVGA 2.2″ LCD color monitor Display update cycle Approx. 3 Hz Display resolution Instantaneous flow rate 0.1 m3/h, 1 L/min, 0.1 CFM Consumption/leakage amount 0.1 m3, 1 L, 1 CF Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) Measurement accuracy Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5 Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5 Zero point error ±0.15% of F.S.*2*6 Static leakage repeatability ±1.0% of RD*4*7 Hysteresis Variable Flow units CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min I/O wiring connection port M12 4-pin connector (male) Detection mode (switchable) ch.1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 ch.2 Instantaneous flow mode/area mode/pulse (? mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 Standard I/O (switchable) Control output (ch.1/ch.2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less Analog output (ch.2) 4 to 20 mA/0 to 20 mA, load resistance: 500 ?or less External input (ch.2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100?or less Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) Communication interface USB USB 2.0 Ethernet Standard IEEE 802.3u (100BASE-TX) Transmission rate 100 Mbps Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable Connector M12 connector (female, D-code) Network function Modbus TCP, EtherNet/IPTM, IO-Link*9 Recording capacity Consumption amount/ leakage amount Approx. 5 years Events 100 Power supply Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2 Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Detection head: ?0 to +60°C 14 to 140°F (no freezing), display unit: ?0 to +55°C 14 to 131°F (no freezing) Relative humidity 5 to 85%RH (no condensation) Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes Shock resistance 100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis Material Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating Detection head Body: PPS/SUS304, rear surface: rubber Mounting/damping bracket SUS304 Weight Approx. 2.8 kg *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.*5 The linearity error characteristic due to the pipe is not included in this value.*6 It is possible to reduce zero point errors by performing an origin adjustment.*7 This is the value within the range where measurement accuracy is guaranteed.*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.?ch.1: Pulse(+) mode?ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*10 The IP65/67 enclosure rating is lost when a USB connection is established.

The post Cảm biến lưu lượng Keyence FD-G200 appeared first on issrp.com.

]]>
Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-g125l/ Tue, 11 Jan 2022 08:40:29 +0000 //issrp.com/product/keyence-fd-g125l/ Clamp-On Gas Flow Meter DN 100A/125A
SKU: FD-G125L
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-G125L appeared first on issrp.com.

]]>
Model FD-G125L Pipe size DN (Diameter Nominal) 100 A, 125 A NPS (Nominal Pipe Size) 4″, 5″ Outer diameter of pipe ø111 to 117 mm 4.37″ to 4.61″, ø138 to 144 mm 5.43″ to 5.67″ Pipe thickness 2.1 to 5.0 mm 0.08″ to 0.2″ Supported pipe materials Iron, steel, stainless steel Supported fluids Air, Nitrogen, other gases*1 Fluid temperature 0 to 60ºC 32 to 140 °F Recommended pressure 0.4 MPa or greater (58 PSI or greater) Rated velocity of flow range Up to 15 m/s Actual flow rate range (typical) m3/h Pipe size 100 A: 470.0Pipe size 125 A: 720.0 L/min Pipe size 100 A: 7800Pipe size 125 A: 12000 CFM Pipe size 100 A: 280.00Pipe size 125 A: 420.00 Standard flow rate range (typical) [CFM] 20°C 68°F 60 psi 0.41 MPa Pipe size 100 A: 1326.34Pipe size 125 A: 1989.51 20°C 68°F 80 psi 0.55 MPa Pipe size 100 A: 1681.49Pipe size 125 A: 2522.23 20°C 68°F 100 psi 0.69 MPa Pipe size 100 A: 2036.63Pipe size 125 A: 3054.95 20°C 68°F 120 psi 0.83 MPa Pipe size 100 A: 2391.78Pipe size 125 A: 3587.67 Display QVGA 2.2″ LCD color monitor Display update cycle Approx. 3 Hz Display resolution Instantaneous flow rate 0.1 m3/h, 1 L/min, 0.1 CFM Consumption/leakage amount 0.1 m3, 1 L, 1 CF Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) Measurement accuracy Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5 Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5 Zero point error ±0.15% of F.S.*2*6 Static leakage repeatability ±1.0% of RD*4*7 Hysteresis Variable Flow units CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min I/O wiring connection port M12 4-pin connector (male) Detection mode (switchable) ch.1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 ch.2 Instantaneous flow mode/area mode/pulse (? mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 Standard I/O (switchable) Control output (ch.1/ch.2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less Analog output (ch.2) 4 to 20 mA/0 to 20 mA, load resistance: 500 ?or less External input (ch.2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100?or less Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) Communication interface USB USB 2.0 Ethernet Standard IEEE 802.3u (100BASE-TX) Transmission rate 100 Mbps Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable Connector M12 connector (female, D-code) Network function Modbus TCP, EtherNet/IPTM, IO-Link*9 Recording capacity Consumption amount/ leakage amount Approx. 5 years Events 100 Power supply Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2 Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Detection head: ?0 to +60°C 14 to 140°F (no freezing), display unit: ?0 to +55°C 14 to 131°F (no freezing) Relative humidity 5 to 85%RH (no condensation) Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes Shock resistance 100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis Material Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating Detection head Body: PPS/SUS304, rear surface: rubber Mounting/damping bracket SUS304 Weight Approx. 2.7 kg *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.*5 The linearity error characteristic due to the pipe is not included in this value.*6 It is possible to reduce zero point errors by performing an origin adjustment.*7 This is the value within the range where measurement accuracy is guaranteed.*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.?ch.1: Pulse(+) mode?ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*10 The IP65/67 enclosure rating is lost when a USB connection is established.

The post Cảm biến lưu lượng Keyence FD-G125L appeared first on issrp.com.

]]>
Keyence FD-G Series, B岷g Gi谩 2025 - issrp.com //issrp.com/product/keyence-fd-g125/ Tue, 11 Jan 2022 08:40:23 +0000 //issrp.com/product/keyence-fd-g125/ Clamp-On Gas Flow Meter DN 100A/125A
SKU: FD-G125
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng t? CO/CQ, hóa đơn VAT

The post Cảm biến lưu lượng Keyence FD-G125 appeared first on issrp.com.

]]>
Model FD-G125 Pipe size DN (Diameter Nominal) 100 A, 125 A NPS (Nominal Pipe Size) 4″, 5″ Outer diameter of pipe ø111 to 117 mm 4.37″ to 4.61″, ø138 to 144 mm 5.43″ to 5.67″ Pipe thickness 3.1 to 6.8 mm 0.122″ to 0.27″ Supported pipe materials Iron, steel, stainless steel Supported fluids Air, Nitrogen, other gases*1 Fluid temperature 0 to 60ºC 32 to 140 °F Recommended pressure 0.4 MPa or greater (58 PSI or greater) Rated velocity of flow range Up to 15 m/s Actual flow rate range (typical) m3/h Pipe size 100 A: 470.0Pipe size 125 A: 720.0 L/min Pipe size 100 A: 7800Pipe size 125 A: 12000 CFM Pipe size 100 A: 280.00Pipe size 125 A: 420.00 Standard flow rate range (typical) [CFM] 20°C 68°F 60 psi 0.41 MPa Pipe size 100 A: 1326.34Pipe size 125 A: 1989.51 20°C 68°F 80 psi 0.55 MPa Pipe size 100 A: 1681.49Pipe size 125 A: 2522.23 20°C 68°F 100 psi 0.69 MPa Pipe size 100 A: 2036.63Pipe size 125 A: 3054.95 20°C 68°F 120 psi 0.83 MPa Pipe size 100 A: 2391.78Pipe size 125 A: 3587.67 Display QVGA 2.2″ LCD color monitor Display update cycle Approx. 3 Hz Display resolution Instantaneous flow rate 0.1 m3/h, 1 L/min, 0.1 CFM Consumption/leakage amount 0.1 m3, 1 L, 1 CF Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) Measurement accuracy Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5 Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5 Zero point error ±0.15% of F.S.*2*6 Static leakage repeatability ±1.0% of RD*4*7 Hysteresis Variable Flow units CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min I/O wiring connection port M12 4-pin connector (male) Detection mode (switchable) ch.1 Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 ch.2 Instantaneous flow mode/area mode/pulse (? mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 Standard I/O (switchable) Control output (ch.1/ch.2) NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less Analog output (ch.2) 4 to 20 mA/0 to 20 mA, load resistance: 500 ?or less External input (ch.2) Short-circuit current: 1.5 mA or less, input time: 20 ms or more Protection circuit Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output Analog input (for volume conversion) M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100?or less Power supplied to pressure sensor Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) Communication interface USB USB 2.0 Ethernet Standard IEEE 802.3u (100BASE-TX) Transmission rate 100 Mbps Cable Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable Connector M12 connector (female, D-code) Network function Modbus TCP, EtherNet/IPTM, IO-Link*9 Recording capacity Consumption amount/ leakage amount Approx. 5 years Events 100 Power supply Power voltage 20 to 30 VDC including 10% ripple (P-P), Class 2 Power consumption 350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) Environmental resistance Enclosure rating IP65/67 (IEC 60529)*10 Ambient temperature Detection head: ?0 to +60°C 14 to 140°F (no freezing), display unit: ?0 to +55°C 14 to 131°F (no freezing) Relative humidity 5 to 85%RH (no condensation) Vibration resistance 10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes Shock resistance 100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis Material Display unit Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating Detection head Body: PPS/SUS304, rear surface: rubber Mounting/damping bracket SUS304 Weight Approx. 2.7 kg *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.*5 The linearity error characteristic due to the pipe is not included in this value.*6 It is possible to reduce zero point errors by performing an origin adjustment.*7 This is the value within the range where measurement accuracy is guaranteed.*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.?ch.1: Pulse(+) mode?ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*10 The IP65/67 enclosure rating is lost when a USB connection is established.